Monitoring the unseen dangers in construction & waste management

You see them and drive past them all the time. Every community has one. Chances are that a neighbor, one of your friends or even a member of your family may work in one. When low pressure sets in and the wind blows in just the right direction, the stench is horrific. But the bad smell is only a hint to the abundant hazards that you could encounter when doing construction work at a local wastewater treatment plant.

The potential for slips, trips and falls exists in wastewater treatment plants just as they do on every construction jobsite. Those basic hazards become more acute when dangerous gases in the air potentially present in such a facility precipitate them. The possibility of severe trauma or even drowning from falling into a confined space, such as a wet well, recirculation pit or a clarifier tank, means the risk associated with doing construction work in or on the site of a wastewater treatment plant may by higher for your workforce than you recognize.

BRIEF DESCRIPTION OF IMAGE

The main gases of concern in wastewater treatment plants are methane, hydrogen sulfide and oxygen. Hydrogen sulfide and methane are the byproducts of the decomposition of organic materials that exist in the waste flows feeding a plant. The buildup of these gases may lead to a lack of oxygen, or, in some cases, explosion when coupled with a source of ignition. But the number of gas hazards present may be too numerous to name. Beyond the most common three gas hazards are the dangers that exist from purifying chemicals, such as ammonia, chlorine, chlorine dioxide or ozone, that are used in the decontamination of the waste and effluent water. The potential for an unlimited number of toxic or explosive gases exists from the chemicals that may be spilled or dumped into the waste system from the industrial base in a community.

Elimination of these gas hazards is virtually impossible, so permanent workers and contractors must depend on reliable gas detection equipment to protect themselves. Although there is not one gas monitor that will protect every worker in every situation, a basic, multi-gas monitor is a good place to start. A standard, four-gas monitor equipped with the proper sensors provides protection from the primary methane, hydrogen sulfide and oxygen hazards. The fourth gas sensor, usually carbon monoxide, can often be replaced with an ammonia or chlorine sensor for additional protection against one of the more prevalent chemical hazards, depending on the treatment plant where your project is located. Upgrading from a four-gas to a five- or six-gas monitor may allow you to advance the level of detection and protect workers from even more of the potential chemical hazards. Unfortunately, protecting workers from the dangers of gas hazards is not as easy as handing them a gas detector and sending them out the door. If your employees do not use their monitors properly, do not understand how their monitors work or do not know how to react to the readings, gas detection devices on your jobsite will not be very effective.

First, the monitor must be turned on. Workers must know how to turn the monitor on and verify that the instrument they are carrying is capable of detecting all of the hazards that they may encounter. Next, if workers want to ensure they are protected, they must confirm that the monitor will actually identify the gases it is supposed to detect. This is accomplished by performing a bump test of the monitor by exposing it to a concentration of each gas it is designed to detect and verifying that the sensor responds and the instrument alarms properly. The simple truth is that the only way to be certain that a gas detector will actually detect gases is to test it with the gas itself. It may sound like a complicated procedure, but it is as simple as placing the monitor on a test stand or docking station equipped with the appropriate gases and having the test run automatically. This should be done each and every time the monitor is used.

The more hazards that a monitor is intended to protect against, the more understanding there must be of how the sensors in the monitor interact. For instance, a user with a monitor having both hydrogen sulfide and chlorine sensors installed must understand that the presence of H2S (hydrogen sulfide) in the atmosphere may negatively affect the reading from the chlorine sensor and thus mask the presence of a dangerous level of chlorine gas in the atmosphere. Users should refer to the instrument manufacturers for information on the cross interference levels and interactions between sensors.

As much as understanding the sensors themselves, the worker has to understand what the proper response is when the monitor does actually detect gas and go into alarm mode. Often, when a gas detector alarms, an untrained user may panic and do something that creates a further danger, or they may ignore the situation because they do not know what to do next. Some new monitors provide alarm action messages that display text instructions to guide workers through the appropriate actions when the monitor alarms. Telling workers to "wear a respirator" or "evacuate" when their instruments alarm will reinforce the hazard training he/she had previously.

Realistically speaking, there may be instances when the monitor is simply not capable of providing the necessary protection quickly enough, and a worker may be overcome by a gas hazard or incapacitated in some other way. It is important that the monitor a worker carries has the means to let others know that he/she is in danger. Instruments may be equipped with a panic button that lets the worker signal others when he is in need of help or a motion detecting alarm that sounds when a worker is motionless for a period of time. More advanced instruments may have the capability of triggering alarms on other workers' instruments when another worker's instrument goes into alarm. These features may be the keys to finding and rescuing a victim of exposure before it is too late.

Gas hazards are an unseen and unavoidable fact in the operations of a wastewater treatment plant. If you are contracted to work at or very near one of these facilities, having the right gas detection equipment and using it properly is the best way to ensure that your crew returns home safely at the end of the workday, even when the wind blows in the right direction.

Unfortunately, protecting workers from the dangers of gas hazards is not as easy as handing them a gas detector and sending them out the door.